LINITHERM PAL HW - The above-rafter thermal insulation system under metal or slated roofs
Picture

PAL HW .pdf

  • The outer leaf can be mechanically attached in any location
  • With integral vapour barrier (additional may be required for warm metal roofing)

​The Highest Spec German Engineering
  • Insulation under metal roof
  • For installation on boarding, metal deck or plywood
  • Derived wood panel bonded in the factory
  • Time-saving and economical installation with full-surface supporting structure
​​
  • ​For PUR(E) energy saving
  • Insulating core made of PU rigid foam
  • λD 0.022 W/(mK)
  • Positive building biology

Over-rafter insulation system - LINITHERM PAL HW
​
Insulation core: PU rigid foam acc. to EN 13165, fire behavior class E acc. to EN 13501-1, coated with aluminum film on both sides

Facing: Covered with a 22 mm P5 particle Board for attaching the slates or metal roofing
​
Edge joints: Tongue & groove pressfit joints on all sides, derived wood panel with T&G and 2mm expansion joint

Please note: When building the sub-roof and the entire roof support structure, the rules of the trade as well as the notes and guidelines in the separate Linzmeier leaflet must be observed.

Coverage 2420 x 580 mm (= calculation measurement)
​

λD (EN 13165)0.022 W/(mK)
​

Thickness total mm    102     122     142      162       182
U-value W/(m²K)         0.25     0.21   0.17      0.15     0.13
1) Roof pitch as specified, and in accordance with the rules of the ZVDH (Central Association of German Roofers).
★ "pure life" certification applies to PU insulation board

​For some time now, metal roofs have gained more and more importance in architecture as they allow attractive roof geometries and therefore more design options. The sports trained in the Cambridge Sports Centre require different hall ceiling heights. To optimally balance the different height requirements, the 5,000m² roof was arched 
Picture
Picture

The top of the steel beams was covered with one layer of trapezoidal steel sheet and a vapour barrier, followed by LINITHERM PAL OSB sloped-roof insulating elements with a thickness of only 135mm.
Builder: Universitiy of Cambridge
Architect: Arup Associates, London
Building project: New building
Product used: Roof insulation LINITHERM PAL OSB 135 mm. PAL HW replaced PAL OSB 2021
​
Installer:  All Metal Roofing Ltd